Our standard feed combiners with TE21 tracking coupler are an important part of complete feed systems and are designed, manufactured, and tested in our factory with Swiss precision in all areas and under the strict control of our quality management. MIRAD feed combiner can be configured with different options, such as additional reject filters, test couplers, various LNA redundancy and HPA switching network. This offers high flexibility and allows the best possible solution for different requirements and the specific needs of our customers.
Ka/Q/V-Band 6-Port Feed Combiner (P/N: 501.77010)
Frequency Range
Polarization
Axial Ratio
Return Loss
Isolation
Rx
Tx1
Tx2
Rx
Tx1
Tx2
Rx
Tx1
Tx2
Rx
Tx1
Tx2
Rx/Rx
Tx1/Tx1
Tx2/Tx2
Tx1/Rx
Tx2/Rx
Rx/Tx1
Rx/Tx2
Tx1/Tx2
Tx1
Tx2
37.5 to 42.5 GHz
27.5 to 30.0 GHz (extension to 31.0 GHz available)
47.2 to 51.4 GHz (extension to 52.4 GHz available)
Dual Circular
Dual Circular
Dual Circular
0.36 dB typ.1 / 0.50 dB max.2
0.45 dB typ.1 / 0.50 dB max.2
0.36 dB typ.1 / 0.50 dB max.2
24 dB typ.1 / 19 dB min.2
20 dB typ.1 / 19 dB min.2
22 dB typ.1 / 19 dB min.2
26 dB typ.1 / 17 dB min.2
20 dB typ.1 / 17 dB min.2
24 dB typ.1 / 17 dB min.2
100 dB min.2
100 dB min.2
85 dB min.2
85 dB min.2
40 dB min.2
250 W per Port (500 W CW simultaneously)
250 W per Port (500 W CW simultaneously)


Ka/Q/V-Band-Band 6-Port Feed Combiner incl. TE21-Mode Monopulse Tracking (P/N: 501.97001)
Frequency Range
Polarization
Axial Ratio
Return Loss
Isolation
Rx
Tx1
Tx2
Trk
Rx
Tx1
Tx2
Trk
Rx
Tx1
Tx2
Rx
Tx1
Tx2
Trk
Rx/Rx
Tx1/Tx1
Tx2/Tx2
Tx1/Rx
Tx2/Rx
Rx/Tx1
Rx/Tx2
Tx1/Tx2
Tx1/Trk
Tx2/Trk
Rx/Trk
Tx1
Tx2
37.5 to 42.5 GHz
27.5 to 30.0 GHz (extension to 31.0 GHz available)
47.2 to 51.4 GHz (extension to 52.4 GHz available)
37.5 to 42.5 GHz
Dual Circular
Dual Circular
Dual Circular
Dual Circular
0.36 dB typ.1 / 0.50 dB max.2
0.45 dB typ.1 / 0.50 dB max.2
0.36 dB typ.1 / 0.50 dB max.2
24 dB typ.1 / 19 dB min.2
20 dB typ.1 / 19 dB min.2
22 dB typ.1 / 19 dB min.2
15 dB typ.1 / 12 dB min.2
26 dB typ.1 / 17 dB min.2
20 dB typ.1 / 17 dB min.2
24 dB typ.1 / 17 dB min.2
100 dB min.2
100 dB min.2
85 dB min.2
85 dB min.2
40 dB min.2
40 dB min.2
40 dB min.2
40 dB min.2
250 W per Port (500 W CW simultaneously)
250 W per Port (500 W CW simultaneously)


1 typical values: Indication for most-common expectable performance within the specified bandwidth.
– for Returnloss and Port/Port Isolation the statistical mode of total passband is represented.
– for Insertionloss and Axial Ratio the statistical mean of total passband is represented
2 min./max. values: Committed specification value, e.g. worst-case performance within limited ranges of passband with tolerance margins