Our standard feed combiners with TE21 tracking coupler are an important part of complete feed systems and are designed, manufactured, and tested in our factory with Swiss precision in all areas and under the strict control of our quality management. MIRAD feed combiner can be configured with different options, such as additional reject filters, , test couplers, various LNA redundancy and HPA switching network. This offers high flexibility and allows the best possible solution for different requirements and the specific needs of our customers.
Q/V-Band 4-Port Feed Combiner (P/N: 501.57010)
Frequency Range
Polarization
Axial Ratio
Return Loss
Isolation
Rx
Tx
Rx
Tx
Rx
Tx
Rx
Tx
Rx/Rx
Tx/Tx
Tx/Rx
Rx/Tx
Tx
37.5 to 42.5 GHz
47.2 to 51.4 GHz (extension to 52.4 GHz available)
Dual Circular
Dual Circular
0.50 dB max.2
0.50 dB max.2
21 dB min.2
21dB min.2
20 dB min.2
20 dB min.2
120 dB min.2
120 dB min.2
150 W per Port
300 W CW simultaneously


Q/V-Band-Band 4-Port Feed Combiner incl. TE21-Mode Monopulse Tracking (P/N: 501.77002)
Frequency Range
Polarization
Axial Ratio
Return Loss
Isolation
Rx
Tx
Trk
Rx
Tx
Trk
Rx
Tx
Rx
Tx
Trk
Rx/Rx
Tx/Tx
Trk/Trk
Tx/Rx
Rx/Tx
Tx/Trk
Rx/Trk
Tx
37.5 to 42.5 GHz
47.2 to 51.4 GHz (extension to 52.4 GHz available)
37.5 to 42.5 GHz
Dual Circular
Dual Circular
Dual Circular
0.50 dB max.2
0.50 dB max.2
21 dB min.2
21 dB min.2
14 dB min.2
20 dB min.2
20 dB min.2
14 dB min.2
120 dB min.2
120 dB min.2
120 dB min.2
40 dB min.2
150 W per Port
300 W CW simultaneously


1 typical values: Indication for most-common expectable performance within the specified bandwidth.
– for Returnloss and Port/Port Isolation the statistical mode of total passband is represented.
– for Insertionloss and Axial Ratio the statistical mean of total passband is represented
2 min./max. values: Committed specification value, e.g. worst-case performance within limited ranges of passband with tolerance margins